<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>EHI</ParameterFamily>
<Syntax>
head hsslope
</Syntax>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Gravure</TextApplies></ListItem>
<ListItem><TextApplies>Japanese_Newspaper_OEM_Engine</TextApplies></ListItem>
<ListItem><TextApplies>Lotem_Quantum</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_400</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_800</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Slave_MCE_Firmware</TextApplies></ListItem>
<ListItem><TextApplies>Thermoflex</TextApplies></ListItem>
<ListItem><TextApplies>Think_Motion_Controller</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_NEWS</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_Series_4</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Used in conjunction with the "hsoffset" parameter to convert the raw results of
a "head power sum" measurement into Watts out of the head.
</text></DescriptionText>
<DescriptionText><text>
The raw reading of the shutter sensor is affected by the "head bpgain"
parameter setting so changing this value will require commensurate changes to
"hsslope".
</text></DescriptionText>
<DescriptionText><text>
This value can only be calibrated if an external power meter is available and
hence this parameter should not be changed from its factory setting.
</text></DescriptionText>
</Description>
<Availability>
<DescriptionText><text>
This parameter is available.
</text></DescriptionText>
</Availability>
<Default>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's default value.</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's minimum and maximum values.</li>
</UnnumberedList>
</Range>
<LastModified>
07-May-2002
</LastModified>
<Notes>
<DescriptionText><text>
Note that the "head power sum" command is only available with thermal head
firmware versions greater than 1.5 and matching MPE code. When available
and calibrated this is the most reliable way to measure power out of the head.
</text></DescriptionText>
</Notes>
<Access>
Normal
</Access>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../prm/ehi_head_hsoffset.xml</LinkAddress><LinkTitle>PRM: head hsoffset</LinkTitle></Link></li>
<li><Link><LinkAddress>../prm/ehi_head_bpgain.xml</LinkAddress><LinkTitle>PRM: head bpgain</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/head_power.xml</LinkAddress><LinkTitle>Command: head power</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:57 2008 PST
</Updated>
<Links>
</Links>
</Parameter>